XP SERIES

The XP167 (120V) and XP267 (230V) are UL listed for use in Class I, Division 1 and 2, Group D Hazardous Locations when used with XP-20F Blowers.

The power supplies are equipped with an arc detection cut-off circuit with alarm capability. In the unlikely event that the static eliminator or cable should arc to ground, the arc detection circuit senses the short and shuts down the power supply within 40 milliseconds. The units include relay contacts that can be used to activate a remote visual or audio alarm and to trigger a PLC, for instance, to shut down the line.

The XP Power Supplies can be mounted within the hazardous location.

 

XPM SERIES

The XPM167and XPM267 Power Supplies are UL/CUL approved for mounting outside of a hazardous location. The XPM167 has an arc detection circuit to shut down the power supply within 40 milliseconds in the event of an arc from the blower or cable. Includes a monitoring system, when operated with the XP-20F, to detect arcing conditions and short circuit on the ionizing points and the cable. Indicator lamps verify input and output voltage status as well as arc detection. Integrated relay contacts allow for remote monitoring of these features.

  • Specifications

    Specifications

    XP167

     
    Input Requirements 120V, 60 Hz
    Output Voltage 7 kV, 3mA max
    Number of outputs for static eliminators 4
    Max Length of static bars which can be attached 300 inches
    Does the unit accept shielded cable N/A
    Acceptable for hazardous locations Yes

    XP267

     
    Input Requirements 230V, 60 Hz
    Output Voltage 7 kV, 3mA max
    Number of outputs for static eliminators 4
    Max Length of static bars which can be attached 300 inches
    Does the unit accept shielded cable N/A
    Acceptable for hazardous locations Yes

    XPM167

     
    Input Requirements 120V, 60Hz
    Output Voltage 7kV, 3mA max
    Number of outputs for static eliminators 4
    Max Length of static bars which can be attached 300 inches
    Does the unit accept shielded cable Yes
    Acceptable for hazardous locations No

    XPM267

     
    Input Requirements 230V, 60Hz
    Output Voltage 7kV, 3mA max
    Number of outputs for static eliminators 4
    Max Length of static bars which can be attached 300 inches
    Does the unit accept shielded cable Yes
    Acceptable for hazardous locations See Overview

    Part Numbers:

     
    XP167 4009088
    XP267 4009089
    XPM167 4009064
    XPM267 4009065